Sound and vibration isolation

Sound insulation limits the transmission of sound from the cinema to neighboring rooms and protects viewers from external noise. Of particular difficulty are the low frequencies and vibrations propagated through building structures.

Room within a room

Depending on the initial conditions, an independent sound insulation shell is used: decoupled walls, a ceiling on vibration insulating fasteners and a floating floor. The composition of the structures, the mass of the layers, the air gaps and the characteristics of the anchorages are determined by calculation. Air and structure-borne noise, as well as indirect sound transmission routes are taken into account.

Airtightness and service penetrations

Doors, ventilation ducts, cable passages and equipment fastenings shall retain the intended characteristics of the shell. The required sound insulation indicators are calculated, including taking into account the frequency range. The final efficiency depends on the original building and the quality of installation.

Frequently asked questions

How is sound insulation different from acoustic treatment?

Sound insulation limits the transmission of sound between rooms, and acoustic treatment controls its behavior inside the cinema.

Is it possible to completely isolate the bass?

The transmission of low frequencies can be significantly reduced, but the degree of insulation achieved is determined by the calculation and design of the building.