acoustic modelling of premises
The Engineering Basis of Quality Sound
Good sound begins long before the acoustic system is installed. Even at the project stage, it is necessary to understand how the sound will spread in a room where unwanted reflections will occur, whether there is enough volume for each viewer and how low frequencies will behave.
At Cinema Project, acoustic modelling is an essential part of the design and delivery of our cinemas. We don’t assign acoustic panels or the location of loudspeakers to the eye: each solution must have an engineering justification and verifiable criteria.
For home cinemas, we focus on CEDIA/CTA-RP22, Dolby recommendations and other applicable industry documents. Depending on the purpose of the object, we also use the relevant standards ISO and GOST. We define a set of requirements and targets for a specific project.
01. Create a digital model of the room
First, we build a separate three-dimensional acoustic model. We take into account the size and shape of the room, the position of the screen, loudspeakers and spectator seats. Then we specify the characteristics of finishing materials, furniture and acoustic structures.
On this model, we check how the sound will behave, compare equipment placement options and select acoustic design. This allows you to detect problems before construction begins, when the fixes do not yet require reworking the finished interior.
02. What exactly are we counting?
Behind professional designations are quite understandable tasks:
- RT60 – Reverberation time. Indicates how long the sound fades indoors. The clarity of the dialogues and the sense of acoustic space depend on this.
- SPL – Sound pressure level. Check whether the volume in the audience is enough and how evenly it is distributed throughout the hall.
- Headroom. Determine whether loudspeakers and amplifiers will be able to play loud episodes without overloading or noticeable distortion.
- Early reflections. Analyze where sound comes to the listener after reflection from walls, floor and ceiling and how this affects the accuracy of the sound scene.
- Low-frequency resonances.Explore why bass may increase in some places and weaken in others, and find ways to improve uniformity.
- C50 and C80 are indicators of clarity. Helps to estimate the ratio of early and late sound energy: C50 is more often used for speech, C80 - for music.
- STI is a speech intelligibility index. Estimates how clearly the listener perceives speech, taking into account acoustics and noise.
- ALcons - assessment of loss of intelligibility of consonants. Additional indicator of comprehensibility of speech; used where appropriate for the task.
We also evaluate the direction of loudspeakers, the direct and reflected sound field and other parameters required for a particular room. Not every indicator is equally important for all types of objects: the composition of the calculation is determined by the purpose of space.
03. From calculation to acoustic design
The result of modelling is not just graphs. Based on them, we determine the number, type and location of sound-absorbing panels, diffusers, low-frequency traps and other structures.
If necessary, adjust the position of loudspeakers, room geometry and finishing materials. Then we check the selected solutions in the model again.
So there is a technically sound project that can be transferred to architects, builders and installers. After implementation, we perform measurements and adjustments: calculation sets the goal, and measurements show how much the actual result corresponds to it.
04. What premises are we calculating?
Acoustic modelling is necessary not only for a dedicated home cinema. We perform calculations for media rooms, lifestyle living rooms, stereo rooms, music zones, home studios, multiroom spaces and outdoor recreation areas, including garden audio systems when they require sound coverage and surround channelsal impact assessment.
We also work with private theaters and concert venues, commercial cinemas, theaters, concert and multifunctional halls. For each type of space, their own criteria are chosen: somewhere in the first place is legibility of speech, somewhere - musical acoustics, uniformity of coverage or compliance with the requirements of a film screening.
05. Independent service or part of a turnkey project
acoustic modelling is always included in the complex design of Cinema Project home cinema on a turnkey basis. At the same time, it can be ordered separately for a new room, an already developed design project, reconstruction or verification of existing solutions.
The customer receives engineering conclusions, recommendations and calculation materials in the agreed composition. They help make decisions based on measurable parameters, not subjective assumptions.
Frequently asked questions
Why do you need an acoustic modelling of a home cinema?
It helps to determine in advance the location of loudspeakers, necessary acoustic design, sound pressure levels and expected sound behavior. Without it, it is difficult to reasonably set requirements for the result.
What is CEDIA/CTA-RP22?
This is an industry recommendation document with criteria for sound reproduction quality in private entertainment spaces. It helps to set measurable goals when designing and evaluating a system. Read more about CEDIA/CTA-RP22 →
How is acoustic modelling different from sound insulation?
Acoustic computation describes the behavior of sound ** inside * a room. The calculation of sound insulation evaluates the transmission of sound **between rooms and through building structures. These are related but different tasks.
Is it possible to calculate the room before the renovation?
Yes, and that's the preferred option. At an early stage, it is easier to change the placement of equipment, wall design and finishing materials without expensive alterations.
Is it possible to order only acoustic modelling without construction?
Yes. It is a standalone service of Cinema Project. We can prepare a calculation and recommendations for your architect, designer or contractor.
Is the service suitable for a studio, stereo room or commercial hall?
Yes. We calculate home and commercial premises for different purposes, selecting methods and targets for specific tasks.
Does a computer model guarantee the perfect sound?